top of page

Fully integrated system design with pre-installation

and pre-commissioning, to reduce commissioning

work on site

Innovative AI bionic thermal balance, 33 % reduction in

all-day system heat loss

Balanced heat dissipation by liquid cooling, the cell

temperature difference ≤ 2.2 ℃

 

Seamless switch ( < 20 ms ) to provide continuous

power supply for off-grid operation

AI monitoring of cell health with early warning, to

manage thermal runaway

PACK, RACK, PCS three-level overcurrent protection

Three-level fire safety design and accurate early

warning of thermal runaway, to prevent fire event

 

Technical Data

ST225kWh-110kW-2h

DC side

Cell type

LFP

System battery configuration

256S1P

Nominal capacity

229 kWh

Nominal voltage range

691.2 V – 934.4 V

AC side ( on-grid )

Nominal power

110 kW

Nominal voltage

400 V

Voltage range

340 V – 440 V

Nominal frequency

50 Hz

Frequency range

45 Hz – 55 Hz

Max.THD of current

< 3 % ( at nominal power )

DC component

< 0.5 % ( at nominal power )

Power factor range

1.0 leading – 1.0 lagging

AC side ( off-grid ) *

Nominal voltage

400 V

Nominal frequency

50 Hz

Max.THD of voltage

< 3 % ( linear load )

Unbalance load capacity

100 %

System parameter

Dimensions ( W * H * D )

1150 * 2450 * 1610 mm

Weight

≤ 3100 kg

Degree of protection

IP55

Auxiliary power supply

Internal power supply ( default ) / External power supply ( optional )

Anti-corrosion degree

C3 ( default ) / C5 ( optional )

Operation humdity range

0 % – 100 % ( non-condensing )

Operation temperature range

-30 ℃ to 50 ℃ ( > 45 ℃ derating )

Altitude

≤ 3000 m

Temperature control method

Intelligent liquid cooling

Noise

≤ 70 dB

Fire suppression system

Flammable gas detector, Smoke detector, Heat detector, Alarm sounder, FK5112, Water

pipeline ( default )

Aerosol ( optional )

Communication interfaces

Ethernet

Communication protocol

Modbus TCP

Standard

IEC 62619, IEC 63056, IEC 62040, IEC 62477, IEC 61000, UN 38.3, NRS 097-2-1

Max.Parallel quantity ( off-grid )

≤ 10

Transformer cabinet parameter *

Transformer capacity

250 kVA

Primary side voltage / Secondary side voltage

400 V / 400 V ( Dyn11 )

Nominal frequency

50 Hz

Dimensions ( W * H * D )

1200 * 2000 * 1200 mm

Weight

≤ 1500 kg

Degree of protection

IP55

Anti-corrosion degree

C3 ( default ) / C5 ( optional )

Operation humidity range

0 % – 100 % ( non-condensing )

Operation temperature range

-30 ℃ to 50 ℃ ( > 45 ℃ derating )

Altitude

≤ 3000 m

Temperature control method

Air cooling

----------------------------------------------------------------------------------

Données techniques ST455kWh-110kW-4h

Côté CC

Type de cellule LFP 3,2 V/280 Ah

Configuration de la batterie du système 256S2P

Capacité nominale 458 kWh

Plage de tension nominale 691,2 V ~ 934,4 V

Côté AC ( sur le-réseau électrique )

Puissance nominale 110 kW

Tension nominale 400 V

Plage de tension 340 V ~ 440 V

Fréquence nominale 50 Hz/60 Hz

Plage de fréquence 45 Hz ~ 55 Hz/55 Hz ~ 65 Hz

THD.max du courant <

3 % (puissance nominale)

Composant CC <

0,5 % (puissance nominale)

Plage de facteurs de puissance 1,0 menant ~ 1,0 retard

Côté AC ( hors du-réseau électrique )*

Tension nominale 400 V

Fréquence nominale 50 Hz / 60 Hz

THD.max de la tension <

3 % ( à la charge linéaire )

Capacité de charge non équilibrée 100 %

Paramètres du système

Dimensions ( L * H * P ) 2152 mm * 2470 mm * 1610 mm

Poids 5300 kg

Indice de protection IP55

Alimentation électrique auxiliaire Alimentation électrique interne ( par défaut )

Alimentation électrique externe ( par défaut )

Degré de protectioncontre la corrosion C5 ( par défaut )

C3 ( en option )

Humidité de fonctionnement 0 % ~ 100 %

Plage de température de fonctionnement -30 °C ~ 50 °C ( > 45 °C de déclassement )

Altitude de fonctionnement max. 3000 m

Méthode de contrôle de la température Refroidissement par liquide intelligent

Bruit ≤ 70 dB ( A ) @ 1 m

Système d’extinction des incendies

Par défaut : détecteur de gaz inflammables, détecteur de fumée, détecteur de chaleur, alarme

sonore, aérosol, sprinkler

Facultatif : système de ventilation

Interface de communication Ethernet

Protocole de communication Modbus TCP

Standard IEC 62619, IEC 63056, IEC 62040, IEC 62477, IEC 61000, UN 38.3, AS/NZS 4777.2, AS/NZS 3000

Quantité.maximale de parallèles ( hors-réseau

électrique ) 10

Paramètres de l’armoire de transformateur *

Capacité du transformateur 250 kVA

Tension côté primaire/Tension côté

secondaire 400 V/400 V ( Dyn11 )

Fréquence nominale 50 Hz/60 Hz

Dimensions ( L * H * P ) 1200 mm * 2000 mm * 1200 mm

Poids 1500 kg

Indice de protection IP55

Degré de protectioncontre la corrosion C5 ( par défaut )

C3 ( en option )

Humidité de fonctionnement 0 % ~ 100 %

Plage de température de fonctionnement -30 °C ~ 50 °C ( > 45 °C de déclassement )

Altitude de fonctionnement max. 3000 m

Méthode de contrôle de la température Refroidissement par air